Development of a quantitative donor risk index to predict short-term mortality in orthotopic heart transplantation

Field Value
Model ID12-088-01
Model NameWeiss 2012
Pubmed ID22093382
First AuthorWeiss
JournalJournal of Heart and Lung Transplantation
Year2012
TitleDevelopment of a quantitative donor risk index to predict short-term mortality in orthotopic heart transplantation
Primary Index ConditionHeart Transplant
Secondary Index ConditionN/A
OutcomeMortality
Model Sample Size17788
Cohort Sample Size22252
Number of Events6637
Follow-Up DurationLong (>6 months)
AUROCNR
Calibration Reported1
CovariatesIschemic time < 2 hours; Ischemic time 2-3.9 hours; Ischemic time 4-5.9 hours; Ischemic time 6-7.9 hours; Ischemic time >=8 hours; Donor age <40 years; Donor age 40-49 years; Donor age >=50 years; Race mismatch; BUN/creatinine ratio >=30
Mesh TermsTo be updated
Number of Validations4

External Validations

Yes
4
0.56
1st Author Year Sample Size AUC Calibration Relatedness
Nilsson 2015 1194 0.55 No N/A
Nilsson 2015 40117 0.56 No N/A
Nilsson 2015 8244 0.56 No N/A
Nilsson 2015 4048 0.59 No N/A