Endovascular stent-graft placement for acute and contained rupture of the descending thoracic aorta
| Field | Value |
|---|---|
| Model ID | 05-027-01 |
| Model Name | Eggebrecht 2005 |
| Pubmed ID | 16273581 |
| First Author | Eggebrecht |
| Journal | Catheter and Cardiovascular Interventions |
| Year | 2005 |
| Title | Endovascular stent-graft placement for acute and contained rupture of the descending thoracic aorta |
| Primary Index Condition | Aortic Disease |
| Secondary Index Condition | N/A |
| Outcome | Mortality |
| Model Sample Size | 17 |
| Cohort Sample Size | 17 |
| Number of Events | NR |
| Follow-Up Duration | Long (>6 months) |
| AUROC | 0.889 |
| Calibration Reported | 1 |
| Covariates | Rupture etiology (thoracic aneurysm [TAA] or acute aortic dissection [AAD] vs. penetratingaortic ulcer [PAU] or transection); Maximum aortic diameter (>5 cm or <5 cm); Estimated lesion length requiring one or more than one stent-graft to be covered; Presence of mediastinal hematoma |
| Mesh Terms | To be updated |
| Number of Validations | 0 |